Works with the machines you already run

Works with your machines.

The gateway speaks the protocols your PLCs already speak. Point the commissioning wizard at a machine, pick your protocol, and it finds the tags live — no rip-and-replace, no new controllers.

PLCs & controllers

The controllers running your lines.

OPC-UA

Ethernet

The modern universal standard — most PLCs built since ~2010 expose an OPC-UA server, across every major vendor. The easy default when a machine supports it.

Siemens S7

Ethernet

S7-300, S7-400, S7-1200 and S7-1500 controllers.

Allen-Bradley (EtherNet/IP)

Ethernet

ControlLogix, CompactLogix and other EtherNet/IP Rockwell controllers, by tag name.

Allen-Bradley (PLC-5 / SLC 500)

Ethernet

Older Rockwell PLC-5 and SLC 500 families over Ethernet.

Allen-Bradley Micro800

Ethernet

Micro800-series micro-PLCs — IP address and go.

Allen-Bradley DH+

Networked

SLC / PLC-5 controllers reached across a legacy DH+ network through a bridge.

Omron

Ethernet

Omron NJ, NX and CJ controllers by symbolic tag.

Mitsubishi (Ethernet)

Ethernet

Mitsubishi Q, L, QnA and iQ-R series over Ethernet.

Mitsubishi (Serial)

Serial

The same Mitsubishi families for machines with no Ethernet port.

LS Electric XGT (Ethernet)

Ethernet

LS Electric XGT-series PLCs over Ethernet.

LS Electric XGT (Serial)

Serial

XGT-series over a serial connection.

CNC, sensors & meters

Machines, meters, and wires.

FANUC CNC (FOCAS)

Ethernet

FANUC CNC controllers — spindle speed, feed rate, alarms and program status.

Modbus TCP

Ethernet

Generic Modbus devices — VFDs, power meters, PLCs, gateways.

Modbus RTU

Serial

Legacy serial Modbus devices over RS-485 / RS-232, usually via a USB adapter.

Direct-wired sensors

Direct-wired

Discrete sensors, relays and switches wired straight into the gateway — no PLC required.

Analog sensors

Direct-wired

4-20mA and 0-10V analog sensors read directly by the gateway.

Anything else

For the stragglers.

Web / XML status feeds

Network

Machines or gateways that publish status over a web or XML endpoint.

Custom / other

Configurable

An escape hatch — anything else with a documented protocol. Bring it to the pilot call and we'll wire it up.

Not sure which one?

Find your machine.

Your machine What it uses
Siemens S7-300 / 400 / 1200 / 1500 Siemens S7
Rockwell ControlLogix / CompactLogix Allen-Bradley (EtherNet/IP)
Rockwell PLC-5 / SLC 500 Allen-Bradley (PLC-5 / SLC 500)
Rockwell Micro800 Allen-Bradley Micro800
Omron NJ / NX / CJ Omron
Mitsubishi Q / L / QnA / iQ-R Mitsubishi
LS Electric XGT LS Electric XGT
FANUC CNC FANUC (FOCAS)
Any modern PLC with OPC-UA OPC-UA
VFDs, meters, generic Modbus Modbus TCP
Legacy serial Modbus Modbus RTU
Discrete or analog sensors, no PLC Direct-wired
Anything else with a documented protocol Custom / other

Something unusual on the floor? The commissioning wizard tests any tag live before you commit — bring your list to the pilot call and we'll tell you exactly what plugs in.

Bring your machine list. We'll tell you exactly what plugs in.

30-day pilot, one line, hardware included — $4,500, fully credited when you expand.